Fecha: 01/02/1987
Idioma: Inglés
Procedencia: Acta Orthop Scand
Ubicación: España

Acta Orthop Scand, feb 1987;58:4-13
Autores:

O.M. Lidwell, R.A. Elson, E.J. Lowbury, W. Whyte, R. Blowers, S.J. Stanley, D. Lowe

Abstract:

To determine the value of ultraclean air in operating rooms, 8,052 operations for total hip- or knee-joint replacement were followed up for 1-4 years. For operations done in ultraclean air, bacterial contamination of the wound, deep joint sepsis, and major wound sepsis were substantially less than for operations done in conventionally ventilated rooms. Sepsis was also less frequent when prophylactic antibiotics had been given. The two precautions acted independently so that the incidence of sepsis after operation in ultraclean air and with antibiotics was much less than that when either was used alone. Wound sepsis was associated with an enhanced risk of joint sepsis. Staphylococcus aureus was the commonest joint pathogen, but infections with other organisms, often considered to be of low pathogenicity, were almost as numerous. Most S. aureus infections were traced to sources in the operating room.
Lidwell, O.M. … [et al.]

Valora este post
Print Friendly, PDF & Email

Deja un comentario

Tu dirección de correo electrónico no será publicada. Los campos requeridos están marcados *

Publicar comentario